Home Products Antibodies Primary antibodies Secondary antibodies Tag antibodies Loading control antibodies Premium polyclonal antibodies Recombinant rabbit mAbs Mouse mAbs Phosphorylated antibodies Methylation antibodies Acetylated antibodies Biochemicals Research Areas
Service & Support Custom Services Support Promotion About Us
Sign In Sign Up

Ubiquitin Antibody  (Cat.#:AYP5777)

A
小A Scan to ask
Host: RabbitClonality: PolyclonalReactivity: Human,Mouse,RatWBIHCELISA
Cat.# AYP5777
Target / gene UBA52
Host Rabbit
Clonality Polyclonal
Reactivity Human, Mouse, Rat
Application WB, IHC, ELISA

Cat.#:AYP5777

SizePrice
50 μL ¥1150.00 Add to cart
100 μL ¥2100.00 Add to cart
  • Information

  • Application guide

  • Related products

  • Immunogen

  • Target data

  • Resources

  • Protocols

  • FAQs

Reactivity Human,Mouse,Rat
Host Rabbit
Clonality Polyclonal
Isotype IgG
Application WBIHCELISA
Dilution WB: 1:500 - 1:2000
IHC: 1:50 - 1:200
Predicted MW 15kDa
Observed MW
Format Liquid
Storage Store at -20℃. Avoid freeze / thaw cycles.
Buffer: PBS with 0.75% BSA,50% glycerol,pH7.3.
Conjugate Unconjugated
Positive MCF7,PC-3,U-937,Mouse liver,Mouse testis,Mouse kidney,Rat liver,Rat testis
Subcellular cytoplasm,cytosol,cytosolic ribosome,endoplasmic reticulum,extracellular exosome,extracellular space,mitochondrial outer membrane,nucleoplasm,nucleus,plasma membrane
Purification Affinity purification

Applications and conditions

Where to start

These starting conditions come from the recommended dilution, validation images, and general assay practice. Titrate for your sample and detection system.

WB Conditions for WB
Recommended dilution 1:500 - 1:2000
Suggested sample / positive control MCF7,PC-3,U-937,Mouse liver,Mouse testis,Mouse kidney,Rat liver,Rat testis
Key conditions Use a fresh lysate, incubate at the recommended dilution, and check the predicted and observed molecular weight
Expected result Expected signal or band near 15kDa
Controls Include a positive sample, a negative sample, and a secondary or isotype control
IHC Conditions for IHC
Recommended dilution 1:50 - 1:200
Suggested sample / positive control MCF7,PC-3,U-937,Mouse liver,Mouse testis,Mouse kidney,Rat liver,Rat testis
Key conditions For paraffin sections, optimize retrieval buffer pH, retrieval time, and primary incubation
Expected result Expected localization: cytoplasm,cytosol,cytosolic ribosome,endoplasmic reticulum,extracellular exosome,extracellular space,mitochondrial outer membrane,nucleoplasm,nucleus,plasma membrane
Controls Include a positive sample, a negative sample, and a secondary or isotype control
ELISA Conditions for ELISA
Recommended dilution See the validation images or contact technical support
Suggested sample / positive control MCF7,PC-3,U-937,Mouse liver,Mouse testis,Mouse kidney,Rat liver,Rat testis
Key conditions Start at the recommended dilution and titrate for your sample and assay
Expected result Expected signal or band near 15kDa
Controls Include a positive sample, a negative sample, and a secondary or isotype control

Related products

More associated products >>

Immunogen

Immunogen Synthesized peptide derived from Human Ubiquitin.
Sequence
View sequence
MQIFVKTLTGKTITLEVEPSDTIENVKAKIQDKEGIPPDQQRLIFAGKQLEDGRTLSDYNIQKESTLHLVLRLRGGIIEPSLRQLAQKYNCDKMICRKCY

Target data

Background Ubiquitin is a highly conserved nuclear and cytoplasmic protein that has a major role in targeting cellular proteins for degradation by the 26S proteosome. It is also involved in the maintenance of chromatin structure, the regulation of gene expression, and the stress response. Ubiquitin is synthesized as a precursor protein consisting of either polyubiquitin chains or a single ubiquitin moiety fused to an unrelated protein. This gene encodes a fusion protein consisting of ubiquitin at the N terminus and ribosomal protein L40 at the C terminus, a C-terminal extension protein (CEP). Multiple processed pseudogenes derived from this gene are present in the genome.
Gene ID 7311
Gene name UBA52
Swiss P62987
Synonym UBA52,CEP52,HUBCEP52,L40,RPL40,Ubiquitin Antibody,Ubiquitin A-52 residue ribosomal protein fusion product 1,60S ribosomal protein L40,UBCEP2,Ubiquitin
Functions Ubiquitin: Exists either covalently attached to another protein, or free (unanchored). When covalently bound, it is conjugated to target proteins via an isopeptide bond either as a monomer (monoubiquitin), a polymer linked via different Lys residues of the ubiquitin (polyubiquitin chains) or a linear polymer linked via the initiator Met of the ubiquitin (linear polyubiquitin chains). Polyubiquitin chains, when attached to a target protein, have different functions depending on the Lys residue of the ubiquitin that is linked: Lys-6-linked may be involved in DNA repair; Lys-11-linked is involved in ERAD (endoplasmic reticulum-associated degradation) and in cell-cycle regulation; Lys-29-linked is involved in lysosomal degradation; Lys-33-linked is involved in kinase modification; Lys-48-linked is involved in protein degradation via the proteasome; Lys-63-linked is involved in endocytosis, DNA-damage responses as well as in signaling processes leading to activation of the transcription factor NF-kappa-B. Linear polymer chains formed via attachment by the initiator Met lead to cell signaling. Ubiquitin is usually conjugated to Lys residues of target proteins, however, in rare cases, conjugation to Cys or Ser residues has been observed. When polyubiquitin is free (unanchored-polyubiquitin), it also has distinct roles, such as in activation of protein kinases, and in signaling.
Research area

Resources

Validation data

Contact technical support for validation images and application examples.

References

No papers are linked yet. Contact technical support for application examples.

Ask for examples
Customer reviews

No reviews yet. After use, you can submit a review and experiment images.

Send feedback
Support

Support can help confirm the application, sample, dilution, controls, and assay conditions.

Support center
Need help with the application?

Send the catalog number, application, sample type, and assay. Support can confirm dilution, controls, and COA or lot documents.

FAQs

Listed applications: WB, IHC, ELISA. Use the validation images and recommended dilution as a starting point.
Send the catalog number and lot through the inquiry form. Support will help with the lot documents.
Use the recommended conditions as a starting concentration. Sample, fixation, and detection system may need a titration.

Protocols

Protocols
AYP5777