Home Products Antibodies Primary antibodies Secondary antibodies Tag antibodies Loading control antibodies Premium polyclonal antibodies Recombinant rabbit mAbs Mouse mAbs Phosphorylated antibodies Methylation antibodies Acetylated antibodies Biochemicals Research Areas
Service & Support Custom Services Support Promotion About Us
Sign In Sign Up

Phospho-eNOS (Ser114) pAb  (Cat.#:ABY1108)

A
小A Scan to ask
Host: RabbitClonality: PolyclonalReactivity: Human,Mouse,RatWBIHCICC/IF
Cat.# ABY1108
Target / gene NOS3
Host Rabbit
Clonality Polyclonal
Reactivity Human, Mouse, Rat
Application WB, IHC, ICC/IF

Cat.#:ABY1108

SizePrice
  • Information

  • Application guide

  • Related products

  • Immunogen

  • Target data

  • Resources

  • Protocols

  • FAQs

Reactivity Human,Mouse,Rat
Host Rabbit
Clonality Polyclonal
Clone no. NA
Isotype IgG
Application WBIHCICC/IF
Dilution WB: 1:500-1:2000,, IF/ICC 1:100-1:500, IHC 1:50-1:200
Predicted MW 133kDa
Observed MW 140KD
Format Liquid
Storage Store at -20℃. Avoid freeze / thaw cycles.
Buffer: PBS with 0.75% BSA,50% glycerol,pH7.5.
Conjugate Unconjugated
Positive Rat placenta,Rat heart
Subcellular Cell membrane. Membrane, caveola. Cytoplasm
Purification 亲和纯化

Applications and conditions

Where to start

These starting conditions come from the recommended dilution, validation images, and general assay practice. Titrate for your sample and detection system.

WB Conditions for WB
Recommended dilution 1:500-1:2000,, IF/ICC 1:100-1:500, IHC 1:50-1:200
Suggested sample / positive control Rat placenta,Rat heart
Key conditions Use a fresh lysate, incubate at the recommended dilution, and check the predicted and observed molecular weight
Expected result Expected signal or band near 140KD
Controls Include a positive sample, a negative sample, and a secondary or isotype control
IHC Conditions for IHC
Recommended dilution See the validation images or contact technical support
Suggested sample / positive control Rat placenta,Rat heart
Key conditions For paraffin sections, optimize retrieval buffer pH, retrieval time, and primary incubation
Expected result Expected localization: Cell membrane. Membrane, caveola. Cytoplasm
Controls Include a positive sample, a negative sample, and a secondary or isotype control
ICC/IF Conditions for ICC/IF
Recommended dilution See the validation images or contact technical support
Suggested sample / positive control Rat placenta,Rat heart
Key conditions Optimize fixation, permeabilization, and blocking, and include a secondary-only control
Expected result Expected fluorescence localization: Cell membrane. Membrane, caveola. Cytoplasm
Controls Include a positive sample, a negative sample, and a secondary or isotype control

Related products

More associated products >>

Immunogen

Immunogen Please contact Support
Sequence Request sequence

Target data

Background Nitric oxide is a reactive free radical which acts as a biologic mediator in several processes, including neurotransmission and antimicrobial and antitumoral activities. Nitric oxide is synthesized from L-arginine by nitric oxide synthases. Variations in this gene are associated with susceptibility to coronary spasm. Alternative splicing and the use of alternative promoters results in multiple transcript variants.
Gene ID 4846
Gene name NOS3
Swiss P29474
Synonym cNOS; Constitutive NOS; EC NOS; EC-NOS; ecNOS; Endothelial nitric oxidase synthase; Endothelial nitric oxide synthase; Endothelial nitric oxide synthase 3; Endothelial NOS; eNOS; Nitric oxide synthase 3 (endothelial cell); Nitric oxide synthase 3; Nitric oxide synthase 3 endothelial cell; Nitric oxide synthase endothelial; Nitric oxide synthase, endothelial; NOS 3; NOS III; NOS type III; NOS3; NOS3_HUMAN; NOSIII;

Resources

Validation data

1 images

Validation images at the top of the page cover WB / IHC / ICC/IF.

References

No papers are linked yet. Contact technical support for application examples.

Ask for examples
Customer reviews

No reviews yet. After use, you can submit a review and experiment images.

Send feedback
Support

Support can help confirm the application, sample, dilution, controls, and assay conditions.

Support center
Need help with the application?

Send the catalog number, application, sample type, and assay. Support can confirm dilution, controls, and COA or lot documents.

FAQs

Listed applications: WB, IHC, ICC/IF. Use the validation images and recommended dilution as a starting point.
Send the catalog number and lot through the inquiry form. Support will help with the lot documents.
Use the recommended conditions as a starting concentration. Sample, fixation, and detection system may need a titration.

Protocols

Protocols
ABY1108